GigaBit SX to TX Tap

Passive monitoring access for 100% visibility

Net Optics GigaBit SX to TX Tap simplifies connecting GigaBit copper monitoring and security devices to SX fiber network links. Convert SX toTX and tap into the link with one device, reducing cost and complexity at the same time. GigaBit SX toTX Taps support passive monitoring of GigaBit links at 1000 Mbps.

Transparent Access
GigaBit SX toTX Taps establish permanent passive access ports without introducing a point of failure or disturbing other network connections. These passive Taps deliver full-duplex monitoring with zero impact on network traffic around the clock.

Security and Visibility
Without an IP address, monitoring devices are isolated from the network, dramatically reducing their exposure to attacks. However, the monitoring device connected to the Tap still sees all full-duplex traffic as if it were in-line, including Layer 1and Layer 2 errors.

Simply Plug It In
Full-duplex monitoring is a snap with supplied cables. All network and monitoring cables necessary for plug-and-play deployment are included with the Tap. Everything you need, right out of the box.

Reliability
For extra uptime protection, Net Optics GigaBit SX to TX Taps offer redundant power connections. Should the primary power source fail, the Tap automatically switches to the backup power source. Power LEDs on the front of the Tap indicate the current power source – even if power is lost and reapplied, there is always zero delay to network traffic.

 

Net Optics GigaBit SX to TX Tap simplifies connecting GigaBit copper monitoring and security devices to SX fiber network links. Convert SX toTX and tap into the link with one device, reducing cost and complexity at the same time. GigaBit SX toTX Taps support passive monitoring of GigaBit links at 1000 Mbps.

Transparent Access

GigaBit SX toTX Taps establish permanent passive access ports without introducing a point of failure or disturbing other network connections. These passive Taps deliver full-duplex monitoring with zero impact on network traffic around the clock.

Security and Visibility

Without an IP address, monitoring devices are isolated from the network, dramatically reducing their exposure to attacks. However, the monitoring device connected to the Tap still sees all full-duplex traffic as if it were in-line, including Layer 1and Layer 2 errors.

Simply Plug It In

Full-duplex monitoring is a snap with supplied cables. All network and monitoring cables necessary for plug-and-play deployment are included with the Tap. Everything you need, right out of the box.

Reliability

For extra uptime protection, Net Optics GigaBit SX to TX Taps offer redundant power connections. Should the primary power source fail, the Tap automatically switches to the backup power source. Power LEDs on the front of the Tap indicate the current power source – even if power is lost and reapplied, there is always zero delay to network traffic.

Splitter Specifications:
Split Ratio:
50/50
Fiber Type: Multimode Corning 62.5/125µm, wavelength 850nm
Insertion Loss: Network Port: 4.5 dB

Operating Specifications:
Operating Temperature:
0°C to 40°C
Storage Temperature: -10°C to 70°C
Relative Humidity: 10% min, 95% max, non-condensing

Mechanical Specifications:
Power Supply: 
Input:
100-240V, 0.5A, 47-63Hz
Output: 12V 1.5A
Dimensions: 1.125" high x 6.5" deep x 4.5” wide

Connectors:
(2) RJ45, 8 pin connectors (monitor ports)
(2) Multimode Duplex LC connectors (network ports)

Cable Interface:

Copper Cable Type: 22-24 AWG unshielded twisted pair cable, CAT5/CAT5E
Link Distance Supported: 100 meters

Fiber Optic Interface:
Connectors: Class I, eye-safe, laser emitter type. These Class I Lasers conform to the applicable requirements per US 21 CFR (J), EN 60825-1, and UL 1950 applications.
Optical Transmitter Wave Length: 850 nm nominal
Output Power: -9.5 dB min, -4 dB max
Optical Receiver Input Sensitivity: 0 dB min, -17 dB max

Optical Receiver Input Sensitivity: -3.0 dB min, -20.0 dB max

Certifications:
Fully RoHS compliant

Part Numbers:
CVT-SX5/GCU
 

 

 

Passive, Secure Technology

 

Warranty

 

Ease of Use

Dotted Lines   Dotted Lines   Dotted Lines
  • Provides passive access at 1000 Mbps without data stream interference or introducing a point of failure
  • Access SX links with GigaBit copper devices without a separate converter
  • Permanent in-line installation without affecting network performance
  • Passes all full-duplex traffic (including errors) from all layers for comprehensive troubleshooting
  • No IP address is needed for the Tap or monitoring device, enhancing monitoring security
  • Redundant power ensures monitoring uptime
  • Fully IEEE 802.3 compliant
  • Fully RoHS compliant
 
  • All Net Optics products come standard with a 1 year manufacturer's warranty
  • Optional 1 or 2 year extended warranty available at time of product purchase
 
  • Front-mounted connectors make installation and operation quick and easy
  • All network and monitoring cables included
  • Silk-screened application diagram illustrates all connections for easy deployment
  • Optional 19-inch rack frames hold up to 3 or 12 Taps
  • Tested and compatible with all major manufacturers’ monitoring devices, including protocol analyzers, probes, and intrusion detection/prevention systems

GigaBit Fiber SX to TX

Dotted Lines

- CVT-SX5/GCU
  Converter, Tap, 1G, SX(62.5µm) to

  Copper 1G, LC, 50:50 split ratio

- RK-3V2
  3-Slot Rack Mount Frame
- RK-12V2
  12-Slot Rack Mount Frame

 

 

 

GigaBit Fiber SX to TX

Dotted Lines

- CVT-SX5/GCU
  Converter, Tap, 1G, SX(62.5µm) to

  Copper 1G, LC, 50:50 split ratio

- RK-3V2
  3-Slot Rack Mount Frame
- RK-12V2
  12-Slot Rack Mount Frame

 Shim