10/100/1000 Multi-Segment Bypass Switch
Insert or remove any in-line appliance without downtime
10/100/1000 Multi-Segment Bypass Switch
Insert or remove any in-line appliance without downtime


The Multi-Segment Bypass Switch provides a 1U, high density, access solution for in-line network security appliances. Each of the four stations operates independently to ensure link protection monitoring of one to four critical network links at any one time. Individual IPS appliances can be connected, maintained or removed without affecting the operation of the remaining stations.
An exclusive Heartbeat feature monitors link status between the Bypass and monitoring tools for enhanced reliability. A configurable Heartbeat packet is injected into the monitor port link to help determine availability of attached monitoring tools. For instance, the Bypass Switch can automatically switch network traffic around an unresponsive IPS appliance – even if the IPS is still powered on. Once the IPS re-establishes a connection, traffic is re-routed to the monitor port for continued operation.
Fail-open Link Fault Protection
For added reliability, each of the stations feature active fail-open network link technology. In the event of power loss to the Bypass Switch, traffic continues to flow through the network links, but is no longer routed to the monitoring tools. Additionally, redundant power supplies are a standard feature.
Each of the Bypass Switches also supports fail-open protection via the Heartbeat packet, in the event power to the monitoring tool fails.
Use of a Bypass Switch ensures that important data on critical links does not fail due to in-line devices. This allows attached monitoring tools to be removed and replaced without network downtime. This alleviates issues with traffic congestion affecting performance and link behavior caused by an IPS. Once an IPS behaves as expected, network traffic is seamlessly diverted to the in-line device again, allowing it to resume its critical functions.
High Performance, Low Latency
The Net Optics throughput and real-time data forwarding hardware helps monitoring tools ensure data protection and does not cause interruption to critical applications like VoIP communications. A Bypass Switch and in-line monitoring tool create a comprehensive solution for improved Infrastructure Prevention and network health.

Operating Specifications:
Operating Temperature: 5ºC to 40ºC
Storage Temperature: -10ºC to 70ºC
Relative Humidity: 10% min, 95% max, non-condensing
Mechanical Specifications:
Input Power: 100-240V, 0.5A, 47-63Hz
Output Power: 12V, 7A
Dimensions: 1.75" high x 11.5" deep x 17" wide
Cable Interface:
Copper Cable Type: 22-24 AWG unshielded twisted pair cable, CAT5/CAT5E
Link Distance Supported: 100 meters
Connectors:
(8) RJ45, 8 pin connectors (monitoring ports)
(8) RJ45, 8 pin connectors (network ports)
(4) DB9 RS232 connectors (management ports)
Certifications:
Fully RoHS compliant
Part Number: BP4-HBCU3
|